The MTC 100 V
is a completely new, highly professional casting system for casting platinum or other high temperature metal to be molten in ceramic crucibles. Instead of a fault-prone centrifugal casting principle, Indutherm relies on a specially developed, automatic pressure and tilting system. This means that the new MTC 100 V can not only be designed to be very compact, but also enables excellent mould filling for both delicate and solid castings. A crucible capacity of 600 g Pt, a possible flask size of up to ø 100 * 150 mm and a maximum temperature of 2,100° C are the key technical data. A multi-frequency infrared pyrometer, automatic tilting with adjustable speed and variable pressure build-up ensure optimal process control and consistently high casting quality.
The new machine is maximum versatile by also working with a graphite crucible to cast alloys for example based on Au, Ag, Cu and others. There is no need to change any hardware components of the induction system. In addition, it can be cast not only in jewellery moulds, but also in ingot moulds.
Excellent form filling thanks to novel high speed pressure and tilting system
- Maximum casting quality by perfect form filling, less porosity andfinest surface quality
- Up to 600 gr Pt, for flasks up to Ø 100*150 mm
- Can also be used to cast gold and silver alloys
- Also for casting ingots
- High quality multi-wavelength infrared pyrometer (option)
- 8 kW induction power, up to 2100° C
- Automatic tilting with adjustable speed
- Adjustable pressure build-up
- Compact design and so much safer than a centrifugal caster!
Data Overview of MTC 100 V
■ standard equipment, ○ optional, - not available
MC 16 | MC 20 V | MC 60 V | MC 100 V | MTC 100 V | |
Power max. / electrical connection | 3,5 kW (230v single phase) | 3,5 kW (230v single phase) | 3,5 kW (230v single phase) | 8 kW (3x400v) | 8 kW (3x400 V) |
Temperature max. | 2000° C | 2000° C | 1300° C | 2000° C | 2100° C |
Crucible Volume | 100g Au 18 ct 110g steel 200g Pl | 100g Au 18 ct 110g steel 200g Pl | 450g Au 18 ct 300g Ag 935 |
450g Au 18 ct 250g steel 500g Pl | 450g Au 18 ct 250g steel 500g Pl |
For use of molds | up to ø 30/50/65/80 mm x 80 mm h | up to ø 30/50/65/80 mm x 80 mm h | up to ø 80/100 mm x 120 mm h | up to ø 80/100 mm x 120 mm h | bis ø 100 mm x 150 mm H |
Control system | by LCD-display, full text readout | by LCD-display, full text readout | by LCD-display, full text readout | by LCD-display, full text readout | by LCD-display, full text readout |
Automatic vacuum function | ■ | ■ | ■ | ■ | ■ |
Automatic overpressure function | ■ | ■ | ■ | ■ | ■ |
Casting also under vacuum only | ■ | ■ | ■ | ■ | |
Vacuum or overpressure after casting | –1 up to +2 bar | –1 up to +3 bar | –1 up to +2 bar | –1 up to +3 bar | –1 up to +3 bar |
Function washing by inert gas | ■ | ■ | ■ | ■ | ■ |
Vibration system | - | ■ | ■ | ■ | ■ |
Supply: cooling water, inert gas argon or nitrogen | ■ | ■ | ■ | ■ | ■ |
Temperature measurement/control | ■ up to 1.300° C, ○ up to 1.600° C | ■ up to 2000° C | ■ up to 1300° C | ■ up to 2000° C | ■ bis 2100° C |
Temperature measurement equipped with an optical pyrometer | - | ■ | - | ■ | up to 2000° C |
Temperature measurement equipped with a dual wave pyrometer | - | ○ | - | ○ | ○ |
RS 232, Ethernet, USB interface, diagnostic system | ■ | ■ | ■ | ■ | ■ |
GSM-modem for remote service | ○ | ○ | ○ | ○ | ○ |
DMS
|
■ | ■ | ■ | ■ | ■ |
InduthermCloud | ○ | ○ | ○ | ○ | ○ |
iThermControl | ○ | ○ | ○ | ○ | ○ |
Vacuum investment mixer Indumix 2+ | ○ | ○ | ○ | ○ | ○ |
Vacuum investment mixer Indumix 3+ | ○ | ○ | ○ | ○ | ○ |
Furnace AK 20 | ○ | ○ | ○ | ○ | ○ |
Furnace AK 50 | ○ | ○ | ○ | ○ | ○ |
Sand blasting cabinet | ○ | ○ | ○ | ○ | ○ |
Vacuum pump up to 8 m³ /h | ○ | ○ | ○ | ○ | ○ |
Vacuum pump up to 21 m³ /h | - | - | ○ | ○ | - |
Floor unit | - | - | - | ○ | - |
Water chiller | ○ | ○ | ○ | ○ | ○ |
Volume ceramic crucible | 30 ccm = 600 g Pt / 250 g steel | ||||
Volume graphite crucible | 25 ccm = 450 g Au 18 ct | ||||
Maximum pressure | 3 bar | ||||
Turbo Pressure PLUS system | ■ | ||||
Vacuum/Inert gas overpressure | ■ | ||||
Temp. measurement by thermocouple | ■, up to 1.300° C | ||||
Vacuum pump | ○ |